Heated Intake System – Rolls-Royce, Bristol, UK
Project
The turnkey supply of an inlet air heating system for a Marine Gas Turbine Engine Test Facility
Features
- Facility inlet air temperature heated by up to 40°C from ambient, for flow rates up to 180 kg/s
Capabilities
- Heated intake system recycles heat dissipated by the facility loadbank system
- Facility loadbanks in conjunction with a generator are the main components in the facility load absorption system
- Heated intake extracts hot air from the loadbanks without creating any additional backpressure that could reduce performance.
- Consistent pressure balance
MDS Project Scope
- Development of a system specification and a trade-off analysis of several solution options including:
- Aerodynamics and acoustics elements
- Flow conditioning and mixing elements
- Air supply fans
- Control valves and dampers
- Silencing components
- Control system